DA180 series basic AC servo drive Function codes
-173-
P6.01
Reverse low
jogging speed
Setting range
Default
Unit
Applicable
mode
-60000
-5
r/min
P
This parameter specifies the speed of slow reverse jogging, which is triggered by the reverse
jogging terminal and high-low jogging speed switching terminal.
P6.01
Data size
16bit
Data format
DEC
Modbus address
2202, 2203
CANopen address
0x2601, 0x00
P6.02
1
Data latching switch
Setting range
Default
Unit
Applicable
mode
01
0
-
P
This parameter specifies whether to enable the data latching switch. If the switch is enabled, the
position information is written to the EEPROM each time the terminal is latched. However, frequent
latching may cause EEPROM damage.
Setting
Meaning
[0]
Disable
1
Enable
P6.02
1
Data size
16bit
Data format
DEC
Modbus address
2204, 2205
CANopen address
0x2602, 0x00
P6.03
Save position
latching
Setting range
Default
Unit
Applicable
mode
01
0
-
P
This parameter specifies whether to save position latching.
Setting
Meaning
[0]
Not save
1
Save
P6.03
Data size
16bit
Data format
DEC
Modbus address
2206, 2207
CANopen address
0x2603, 0x00
P6.04
Forward high
jogging speed
Setting range
Default
Unit
Applicable
mode
06000
60
r/min
P
This parameter specifies the speed of fast forward jogging, which is triggered by the forward
jogging terminal and high-low jogging speed switching terminal.
P6.04
Data size
16bit
Data format
DEC
Modbus address
2208, 2209
CANopen address
0x2604, 0x00