DA180 series basic AC servo drive Function codes
-178-
6.8 PTP control (groups PtP0, PtP1, and PtP2)
PtP0.00
Control word of
segment 00
Setting range
Default
Unit
Applicable
mode
00x7FFFFFFF
0x00000000
-
P
General description
Data bit
Name
Function
Bit03
MODE
PTP running mode.
Bit47
OPT
PTP attribute.
Bit811
ACC
ACC/DEC time index.
Bit1215
SPD
Target speed index.
Bit1619
DLY
Delay time index.
Bit2023
CYL
Number of cycles for executing the current segment.
Bit2430
JMP
The program jumps to the next segment.
Description for MODE
Setting
Meaning
0
The program stops after the current segment is executed.
1
The program jumps to the next segment after the current segment is
executed.
2
The program stops after circular execution. If CMD is 1, the circulation is
invalid.
3
The program jumps to the next segment after circular execution. If CMD is 1,
the circulation is invalid.
Description for OPT
Data bit
Name
Function
Bit4
INS
Insertion. The current segment can suspend segments that are
being executed or not executed.
Bit5
OVLP
Overlap. The current segment and next segment can overlap
and then be executed.
Bit67
CMD
Position command type: 0 indicates incremental position while 1
indicates absolute position.

Table of Contents