DA180 series basic AC servo drive Function codes
-123-
P2.85
Torque
feed-forward
Setting range
Default
Unit
Applicable
mode
01
0
-
P
S
T
This parameter specifies torque feed-forward.
Setting
Meaning
[0]
Speed command
1
Position command
P2.85
Data size
16bit
Data format
DEC
Modbus address
1570, 1571
CANopen address
0x2255, 0x00
6.4 I/O management (group P3)
6.4.1 Digital input/output
P3.00
1
Input of digital 1
Setting range
Default
Unit
Applicable
mode
0x0000x136
0x003
-
P
S
T
This parameter specifies the input of digital 1. It is in the hexadecimal format.
In the expression of 0x*——, * indicates the valid mode, the value 0 indicates the input is valid
when the optical coupler is conductive, while the value 1 indicates the input is valid when the
optical coupler is not conductive.
In the expression of 0x**, ** indicate the function settings. The detailed function settings are
listed in the following.
Function
Symbol
Setting
Applicable
mode
Valid when
optical coupler
not conducted
Valid when
optical
coupler
conducted
Invalid
0x100
0x000
P
S
T
Disabling forward drive
POT
0x101
0x001
P
S
T
Disabling reverse drive
NOT
0x102
0x002
P
S
T
Enabling servo
SON
0x103
0x003
P
S
T
Clearing alarms
CLA
0x104
0x004
P
S
T
Switching control modes
MCH
x105
0x005
P
S
T
Switching gains
PLC
0x106
0x006
P
S
T
Clearing residual pulses
RPC
0x107
0x007
P
Inhibiting command pulses
LL
0x108
0x008
P
Switching torque limits
TLC
0x109
0x009
P
S
Internal-speed command 1
SPD1
0x10A
0x00A
S
T
Internal-speed command 2
SPD2
0x10B
0x00B
S
T
Internal-speed command 3
SPD3
0x10C
0x00C
S

Table of Contents