EasyManua.ls Logo

INVT DA180-S2R8SG0

INVT DA180-S2R8SG0
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA180 series basic AC servo drive Function codes
-223-
R0.58
Disk single-turn position
Setting range
Accuracy
Unit
-(2
31
-1)(2
31
-1)
1
pulse
This parameter displays the position in a single turn of the disk based on the setting of P5.70.
R0.58
Data size
32bit
Data format
DEC
Modbus address
4122, 4123
CANopen address
0x303A, 0x00
R0.60
Medium-power motor
temperature
Setting range
Accuracy
Unit
-55200
1
°C
This parameter displays the current temperature of the medium-power motor with temperature
resistor KTY84-130. Temperature is sampled only when P4.45 is not zero.
R0.60
Data size
32bit
Data format
DEC
Modbus address
4126, 4127
CANopen address
0x303C, 0x00
R0.61
Environment
temperature
Setting range
Accuracy
Unit
-55.0180.0
0.1
°C
This parameter displays the current environment temperature.
R0.61
Data size
16bit
Data format
DEC
Modbus address
4028, 4029
CANopen address
0x303D, 0x00
R0.99
Fault code
Setting range
Accuracy
Unit
-3276832767
1
-
This parameter displays the fault code, in which the thousands and hundreds digits are the main
fault code and the tens and ones digits are the sub fault code.
R0.99
Data size
16bit
Data format
DEC
Modbus address
4198, 4199
CANopen address
0x3063, 0x00

Table of Contents