DA180 series basic AC servo drive Function codes
-91-
See the descriptions for P0.46–P0.53.
You need to set either P3.26 [Function of AI 1] or P3.27 [Function
of AI 2] to 3 [Speed command] and set associated parameters
according to the actual situation.
The communication bus interface can be used to receive speed
commands from the upper computer. If P4.10 is 1 [Bus input], the
motor speed can be changed by P4.13 [Bus speed command].
See the descriptions for P4.10 and P4.13.
High-resoluti
on internal
speed
Speed command
direction setting
This parameter specifies the method for specifying the direction in a speed command when P0.40
is 0 or 1, and the speed command symbol is S-SIGN.
This parameter specifies the gain of analog input 1, the gain unit is associated with P3.26.
Note:
Analog input 1 indicates the signal input from the terminals (that is, AD1 and GND,
corresponding to pin 1 and pin 5) of analog input 1 of the CN1 plug.
The voltage only in the -10V–+10V range can be applied to the connection between AD1 and
GND. Otherwise, the drive may be damaged.
Application example: