DA180 series basic AC servo drive Function codes
-93-
P0.46
Internal speed 1/speed
limit 1
Setting range
Default
Unit
Applicable
mode
-2000020000
100
r/min
S
T
P0.47
Internal speed 2/speed
limit 2
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
T
P0.48
Internal speed 3/speed
limit 3
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
T
P0.49
Internal speed 4/speed
limit 4
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
T
P0.50
Internal speed 5
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
P0.51
Internal speed 6
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
P0.52
Internal speed 7
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
P0.53
Internal speed 8
Setting range
Default
Unit
Applicable
mode
-2000020000
0
r/min
S
The servo drive supports the 8-step internal speed commands and 4-step internal speed limits.
Control
mode
Setting of
P0.40
SPD3
SPD2
SPD1
Associated parameter
and setting
Speed
0
0
0
0
P0.46 Internal speed 1
0
0
1
P0.47 Internal speed 2
0
1
0
P0.48 Internal speed 3
0
1
1
P0.49 Internal speed 4
1
0
0
P0.50 Internal speed 5
1
0
1
P0.51 Internal speed 6
1
1
0
P0.52 Internal speed 7
1
1
1
P0.53 Internal speed 8
Torque
0
0
0
0
P0.46 Speed limit 1
0
0
1
P0.47 Speed limit 2
0
1
0
P0.48 Speed limit 3
0
1
1
P0.49 Speed limit 4