DA180 series basic AC servo drive Function codes
-160-
P5.03
Jogging ACC/DEC
time
Setting range
Default
Unit
Applicable
mode
210000
100
ms
P
This parameter specifies the acceleration or deceleration time at jogging. The setting of this
parameter corresponds to the time taken to accelerate from the zero speed to the rated rotation
speed. If you need to improve the speed from zero to 50% of the rated speed, the time taken to
reach the target speed is 50% of the time specified by this parameter.
P5.03
Data size
16bit
Data format
DEC
Modbus address
2006, 2007
CANopen address
0x2503, 0x00
P5.04
Jogging wait time
Setting range
Default
Unit
Applicable
mode
010000
100
ms
P
This parameter specifies the wait time at jogging. The setting of this parameter corresponds to the
time from jogging starting to the actual running or to the time taken to wait for next displacement
after the current displacement.
P5.04
Data size
16bit
Data format
DEC
Modbus address
2008, 2009
CANopen address
0x2504, 0x00
P5.05
Jogging cycles
Setting range
Default
Unit
Applicable
mode
010000
1
-
P
This parameter specifies the number of jogging cycles. For details, see the description for P5.00.
P5.05
Data size
16bit
Data format
DEC
Modbus address
2010, 2011
CANopen address
0x2505, 0x00