Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-109-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
on processing
LED ones: Write action
0: Write with response: the inverter will respond to all
reading and writing commands of upper computer.
1: Write without response: the inverter only responds
to the reading command other than the writing
command of upper computer. The communication
efficiency can be increased by this method.
LED tens: Communication encryption processing
0: Communication encrypting is valid
1: Communication encrypting is invalid
P17 Group Monitoring function
P17.00
Setting
frequency
Display current set frequency of the inverter
Range: 0.00Hz~P00.03
0.00Hz
P17.01
Output
frequency
Display current output frequency of the inverter
Range: 0.00Hz~P00.03
0.00Hz
P17.02
Ramp
reference
frequency
Display current ramp reference frequency of the
inverter
Range: 0.00Hz~P00.03
0.00Hz
P17.03
Output
voltage
Display current output voltage of the inverter
Range: 0~1200V
0V
P17.04
Output
current
Display current output current of the inverter
Range: 0.0~3000.0A
0.0A
P17.05
Motor speed
Display the rotation speed of the motor.
Range: 0~65535RPM
0RPM
P17.06
Torque
current
Display current torque current of the inverter
Range: -3000.0~3000.0A
0.0A
P17.07
Exciting
current
Display current exciting current of the inverter
Range: -3000.0~3000.0A
0.0A
P17.08
Motor power
Display current power of the motor. 100.0%
corresponds to motor rated power, positive in
electromotion state and negative in power generation.
Setting range: -300.0%~300.0% (relative to the rated
power of the motor)
0.0%