Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-145-
frequency of
direct start
P01.02
Retention
time of
starting
frequency
0.00~50.00s
0.00s
P01.03
The braking
current
before
starting
0.0~100.0%
0.0%
P01.04
The braking
time before
starting
0.00~50.00s
0.00s
P01.05
ACC/DEC
selection
0: Linear type
1: S curve type
0
P01.06
S curve start
proportion
0.0~50.0% (ACC/DEC time)
30.0%
P01.07
S curve end
proportion
0.0~50.0% (ACC/DEC time)
30.0%
P01.08
Stop mode
0: Decelerate to stop
1: Coast to stop
0
P01.09
Starting
frequency of
DC braking
0.00Hz~P00.03 (the Max. output frequency)
0.00Hz
P01.10
Waiting time
of DC braking
0.00~50.00s
0.00s
P01.11
DC braking
current
0.0~100.0%
0.0%
P01.12
DC braking
time
0.00~50.00s
0.00s
P01.13
Dead time of
FWD/REV
rotation
0.0~3600.0s
0.0s
P01.14
Shifting
between
0: Switch after zero frequency
1: Switch after the starting frequency
2