Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-82-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
make the password protection invalid.
After the set users password becomes valid, if the
password is incorrect, users cannot enter the
parameter menu. Only correct password can make
the user check or modify the parameters. Please
remember all users’ passwords.
Retreat editing state of the function codes and the
password protection will become valid in a minute. If
the valid password is available, press PRG/ESC to
enter into the editing state of the function codes, and
then “0.0.0.0.0” will be displayed. Unless input right
password, the operator cannot enter into it.
Note: Restoring to the default value can clear the
password, please use it with caution.
P07.01
Parameter
copy
The function code determines the manner of
parameters copy.
0: No operation
1: Upload the local function parameter to the keypad
2: Download the keypad function parameter to local
address (including the motor parameters)
3: Download the keypad function parameter to local
address (excluding the motor parameter of P02 and
P12 group)
4: Download the keypad function parameters to local
address (only for the motor parameter of P02 and
P12 group)
Note: After completing the 1~4 operations, the
parameter will restore to 0 automatically; the
function of upload and download excludes the
factory parameters of P29.
0
P07.02
QUICK/JOG
function
selection
0: No function
1: Jogging. Press QUICK/JOG to begin the jogging
running.
1