Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-83-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
2: Shift the display state by the shifting key. Press
QUICK/JOG to shift the displayed function code from
right to left.
3: Shift between forward rotations and reverse
rotations. Press QUICK/JOG to shift the direction of
the frequency commands. This function is only valid
in the keypad commands channels.
4: Clear UP/DOWN settings. Press QUICK/JOG to
clear the set value of UP/DOWN.
5: Coast to stop. Press QUICK/JOG to coast to stop.
6: Shift the reference manner of running commands.
Press QUICK/JOG to shift the reference manner of
running commands.
7: Quick commission mode (commission according to
the non-factory parameter)
Note: Press QUICK/JOG to shift between forward
rotation and reverse rotation, the inverter does
not remember the state after shifting during
powering off. The inverter will run in the running
direction set according to parameter P00.13
during next powering on.
P07.03
Shifting
sequence
selection of
QUICK/JOG
commands
When P07.02=6, set the shifting sequence of running
command channels.
0: Keypad control terminals control
communication control
1: Keypad control←→terminals control
2: Keypad control←→communication control
3: Terminals control←→communication control
0
P07.04
STOP/RST
stop
function
STOP/RST is valid for stop function. STOP/RST is
valid in any state for the fault reset.
0: Only valid for the keypad control
1: Both valid for keypad and terminals control
2: Both valid for keypad and communication control
0