Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-95-
Detailed instruction of parameters
0: Normal mode
1: The fan keeps running after power on
0x00~0x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-phase modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit mode
0: Low-speed carrier frequency limit mode 1, the
carrier frequency will limit to 2k if it exceeds 2k at low
speed
1: Low-speed carrier frequency limit mode 2, the
carrier frequency will limit to 4k if it exceeds 4k at low
speed
2: No limit
Over
commission
selection
0x00~0x11
LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overcommission; in zone 1
1: Heavy overcommission; in zone 2
0x000~0x1223
LED ones: frequency enable selection
0: Both ∧/∨ key and digital potentiometer
adjustment are valid
1: Only ∧/∨ key adjustment is valid
2: Only digital potentiometer adjustment is valid
3: Neither ∧/∨ key nor digital potentiometer