Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
2.1.8 GENERAL WARNINGS
l
Incorrect installation and configuration of the system decreases or inhibits the protective function of the
system. Follow the instructions provided in this manual for correct installation, configuration and validation of
the system.
l
Changes to the system configuration may compromise the protective function of the system. After any
changes made to the configuration, validate correct functioning of the system by following the instructions
provided in this manual.
l
If the system configuration allows access to the dangerous area without detection, implement additional
safety measures (e.g., guards).
l
The presence of static objects, in particular metallic objects, within the field of view may limit the efficiency of
sensor detection. Keep the sensor field of view unobstructed.
l
The system protection level (SIL 2, PL d) must be compatible with the requirements set forth in the risk
assessment.
l
Check that the temperature of the areas where the system is stored and installed is compatible with the
storage and operating temperatures indicated in the technical data of this manual.
l
Radiation from this device does not interfere with pacemakers or other medical devices.
2.1.9 WARNINGS FOR THE RESTART PREVENTION FUNCTION
l
The restart prevention function is not guaranteed in blind spots. If required by the risk assessment, implement
adequate safety measures in those areas.
l
Machinery restarting must be enabled only in safe conditions. The button for the restart signal must be
installed:
o
outside of the dangerous area
o
not accessible from the dangerous area
o
in a point where the dangerous area is fully visible
2.1.10 RESPONSIBILITY
The machinery manufacturer and system installer are responsible for the operations listed below:
l
Providing adequate integration of the safety output signals of the system.
l
Checking the monitored area of the system and validating it based on the needs of the application and risk
assessment.
l
Following the instructions provided in this manual.
2.1.11 LIMITS
l
If the static object detection option is disabled, the system cannot detect the presence of people who are
immobile and not breathing or objects within the dangerous area.
l
The system does not offer protection from pieces ejected from the machinery, from radiation, and objects
falling from above.
l
The machinery command must be electronically controlled.
2.1.12 DISPOSAL
In safety-related applications, comply with the mission time reported in "General specifications" on page105.
For decommissioning follow the instructions reported in "Disposal" on page133.