3. Get to know Inxpect SRE 200 Series
3.9.3 Data exchanged through MODBUS
The following table details the data exchanged through the MODBUS communication:
Data type Description
Communication
direction
Unsafe SYSTEM STATUS DATA
Control unit:
l
internal status
l
status of each of the four OSSDs
l
status of each single channel and dual channel input
l
revision information
Sensor:
l
status of each detection field (target detected or not) or error
status
l
muting status
l
revision information
from the control
unit
Unsafe DYNAMIC CONFIGURATION STATUS
l
ID of the dynamic configuration currently active
l
signature (CRC32) of the dynamic configuration ID currently active
from the control
unit
Unsafe TARGET DATA
l
Current distance and angle of the targets detected by each sensor.
For each detection field of each sensor, only the closest target to
the sensor is considered.
from the control
unit
Unsafe DIAGNOSTIC DATA
Control unit:
l
internal status with an extended description of the error condition
Sensor:
l
internal status with an extended description of the error condition
from the control
unit
3.10 System configuration
3.10.1 System configuration
The control unit parameters have their own default values that can be modified via the Inxpect Safety application
(see "Configuration application parameters" on page118).
When a new configuration is saved, the system generates the configuration report.
Note: after a physical change of the system (e.g., new sensor installed), the system configuration must be updated
and a new configuration report must be generated, too.
3.10.2 Dynamic system configuration
Inxpect SRE 200 Series allows a real-time adjustment of the most important system parameters, providing the
means to switch dynamically among different preset configurations. Via the Inxpect Safety application, once the
first system configuration (default configuration) has been set, it is possible to set alternative presets to allow a
dynamic real-time reconfiguration of the monitored area. The alternative presets are 7 through digital input and
31 through Fieldbus (if available).
3.10.3 Dynamic system configuration parameters
These are the programmable parameters for each sensor:
l
detection field (from 1 to 4)
These are the programmable parameters for each detection field:
l
angular coverage
l
detection distance