CONTROLUNIT Detection exit (field #n)
SENSOR #k Detection exit
9.3 INFOevents
9.3.1 System Boot
Every time the system is powered up, the event is logged reporting the incremental count of the boot from the
beginning of the life of the device.
Format: System Boot #n
Example:
0 2020/11/18 16:47:25 [INFO] CONTROLUNIT SYSTEMBOOT #60
9.3.2 System configuration
Every time the system is configured, the event is logged reporting the incremental count of the configuration from
the beginning of the life of the device.
Format: System configuration #3
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT System configuration #3
9.3.3 Factory reset
Every time a factory reset is required, the event is logged.
Format: Factory reset
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Factory reset
9.3.4 Stop signal
If configured, every change of the Stop Signal is logged as ACTIVATION or DEACTIVATION.
Format: Stop signal ACTIVATION/DEACTIVATION
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Stop signal ACTIVATION
9.3.5 Restart signal
If configured, every time the system is waiting for the restart signal or the restart signal is received, the event is
logged as WAITING or RECEIVED.
Format: Restart signal WAITING/RECEIVED
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Restart signal RECEIVED
9.3.6 Detection access
Every time motion is detected, a detection access is logged with additional parameters depending on the
selected verbosity level: the detection field number, the sensor which detected the motion, the detection
distance (in mm) and the detection angle (°) (see "Verbosity level for detection access and exit events" on the
previous page).
Format: Detection access (field #n, distance mm/azimuth°)
9. Troubleshooting
Inxpect SRE 200 Series | Instruction manual v1.5 DEC 2023|Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
93