8. Installation and use procedures
Contents
This section includes the following topics:
8.1 Before installation 65
8.2 Install Inxpect SRE 200 Series 65
8.3 Set the sensor inclination with a 1° precision 72
8.4 Configure Inxpect SRE 200 Series 75
8.5 Validate the safety functions 77
8.6 Manage the configuration 81
8.7 Other procedures 82
8.1 Before installation
8.1.1 Materials required
l
Two tamper-proof screws (see "Tamper-proof screws specifications" on page108) to mount each sensor.
l
Cables to connect the control unit to the first sensor and the sensors to one another (see "CAN bus cables
recommended specifications" on page108).
l
A data USB cable with a micro-USB connector (micro-B type) or, only if the Ethernet port is available, an
Ethernet cable to connect the control unit to the computer.
l
A bus terminator (product code: 07000003) with resistance of 120 Ω for the last sensor of the CAN bus.
l
A screwdriver for tamper-proof screws (see "Tamper-proof screws specifications" on page108) to be used
with the Hex pin security bit supplied in the control unit package.
8.1.2 Operating system required
l
Microsoft Windows 10 or later
l
Apple OS X 11.0 or later
8.1.3 Install the Inxpect Safety application
Note: if the installation fails, the dependencies needed by the application may be missing. Update your operating
system or contact our Technical Support to receive assistance.
1. Download the application from the https://tools.inxpect.com website and install it on the computer.
2. With Microsoft Windows operating system, download and install from the same site also the driver for
USB connection.
8.1.4 Initiate Inxpect SRE 200 Series
1. Calculate the position of the sensor (see "Sensor position" on page53) and the depth of the dangerous area
(see "Dangerous area calculation" on page58).
2. " Install Inxpect SRE 200 Series".
3. "Configure Inxpect SRE 200 Series".
4. "Validate the safety functions".
8.2 Install Inxpect SRE 200 Series
8.2.1 Install procedure
1. "Install the control unit".
2. Optional. "Mount 3-axes bracket".
3. "Install the sensors".
4. "Connect the sensors to the control unit".
Note: connect the sensors to the control unit off-site if access to the connectors becomes difficult once
installed.