Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
10. Maintenance
Accessories
Product Part number
Bus terminator 07000003
3-axes bracket 90302ZAA
Rough indoor adjustable support
kit
90302ZAC
Rough outdoor adjustable support
kit
90302ZAD
microSD Industrial Grade X0000011
10.2 Extraordinary maintenance
10.2.1 Machinery maintenance technician
The machinery maintenance technician is a qualified person with the administrator privileges required to modify
the configuration of Inxpect SRE 200 Series through the Inxpect Safety application and perform maintenance and
troubleshooting.
10.2.2 Control unit firmware update
1. Download the latest Inxpect Safety application version from the https://tools.inxpect.com website and install
it on your computer.
2. Connect to the control unit via Ethernet and log in as Admin user.
Note: update via USB is available only for C203A andC203B.
3. In Settings > General, check if a new update is available.
4. Update without disconnecting from or turning off the device.
10.2.3 Replace a sensor: System recondition function
The system recondition function is useful for replacing an existing sensor without changing current settings. The
function can be enabled through digital inputs (System recondition or Restart signal + System recondition) or
via Fieldbus (System recondition only).
WARNING! If the system recondition function has been configured through the safety Fieldbus and
the digital inputs, the function can be used from both.
Note: keep the scene static while running the system recondition function so that the anti-tampering functions can
save their references.
Note: while running the system recondition function, the system goes to the safe state, deactivating the OSSDs,
until the process is completed.
1. Configure the digital inputs or Fieldbus to perform the system recondition function.
2. Connect a sensor without Node ID in the same position of the CANbus line as the replaced sensor.
Note: only one sensor at a time must be connected to complete the procedure correctly.
3. Activate the function (via digital inputs or Fieldbus) and wait for the operation to be performed. See
"Control unit LED" on page85 to know which is the system status.
The following actions are performed:
l
The first available Node ID is assigned to the new sensor.
l
The previous configuration of the system is applied (APPLY CHANGES operation).
l
The event is logged in the reports archive (Settings > Activity History > Configuration reports page) with
the following strings in the User, PC column:
o
“sys-recondition-i” when the function is performed via digital input
o
“sys-recondition-f” when Fieldbus is used
Note: for more details, see "Digital input signals" on page122.