EasyManua.ls Logo

Inxpect SRE 200 Series - 9.4 ERROR events (control unit)

Inxpect SRE 200 Series
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Session OPEN via USB
9.3.13 Validation
Every time a validation activity starts or ends on the device, it is logged. The interface used (USB/ETH) is logged
as well.
Format: Validation STARTED/ENDED via USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Validation STARTED via USB
9.3.14 Log download
Every time a log download is performed on the device, it is logged. The interface used (USB/ETH) is logged as
well.
Format: Log download via USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Log download via USB
9.4 ERRORevents (control unit)
9.4.1 Introduction
A diagnostic error is logged every time the periodic diagnostic functions detect a coming or going fault on the
control unit.
9.4.2 Temperature errors (TEMPERATUREERROR)
Error Meaning
BOARD TEMPERATURE TOOLOW Board temperature below minimum
BOARD TEMPERATURETOOHIGH Board temperature above maximum
9.4.3 Control unit voltage errors (POWERERROR)
Error Meaning
Control unit voltage
UNDERVOLTAGE
Undervoltage error for the indicated voltage
Control unit voltage
OVERVOLTAGE
Overvoltage error for the indicated voltage
ADC CONVERSION
ERROR
ADC conversion error in the micro-controller
The following table describes the control unit voltage:
Screen printing Description
VIN Power supply voltage (+24 V DC)
V12 Internal supply voltage
V12 sensors Sensors power supply voltage
VUSB USB port voltage
VREF Inputs reference voltage (VSNS Error)
ADC Analog-digital converter
9. Troubleshooting
Inxpect SRE 200 Series | Instruction manual v1.5 DEC 2023|Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
95

Table of Contents