Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Session OPEN via USB
9.3.13 Validation
Every time a validation activity starts or ends on the device, it is logged. The interface used (USB/ETH) is logged
as well.
Format: Validation STARTED/ENDED via USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Validation STARTED via USB
9.3.14 Log download
Every time a log download is performed on the device, it is logged. The interface used (USB/ETH) is logged as
well.
Format: Log download via USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLUNIT Log download via USB
9.4 ERRORevents (control unit)
9.4.1 Introduction
A diagnostic error is logged every time the periodic diagnostic functions detect a coming or going fault on the
control unit.
9.4.2 Temperature errors (TEMPERATUREERROR)
Error Meaning
BOARD TEMPERATURE TOOLOW Board temperature below minimum
BOARD TEMPERATURETOOHIGH Board temperature above maximum
9.4.3 Control unit voltage errors (POWERERROR)
Error Meaning
Control unit voltage
UNDERVOLTAGE
Undervoltage error for the indicated voltage
Control unit voltage
OVERVOLTAGE
Overvoltage error for the indicated voltage
ADC CONVERSION
ERROR
ADC conversion error in the micro-controller
The following table describes the control unit voltage:
Screen printing Description
VIN Power supply voltage (+24 V DC)
V12 Internal supply voltage
V12 sensors Sensors power supply voltage
VUSB USB port voltage
VREF Inputs reference voltage (VSNS Error)
ADC Analog-digital converter