9.5.9 Temperature errors (TEMPERATUREERROR)
Error Meaning
BOARD TEMPERATURE TOOLOW Board temperature below minimum
BOARD TEMPERATURETOOHIGH Board temperature above maximum
CHIP TEMPERATURE TOO LOW Internal chip below minimum
CHIP TEMPERATURE TOO HIGH Internal chip above maximum
IMU TEMPERATURE TOO LOW IMU below minimum
IMU TEMPERATURE TOO HIGH IMU above maximum
9.5.10 MSS error and DSS error (MSS ERROR/DSS ERROR)
Error detected by diagnostics relative to the internal micro-controllers (MSS and DSS), their internal peripherals
or memories
9.6 ERRORevents (CANbus)
9.6.1 Introduction
A diagnostic error is logged every time the periodic diagnostic functions detect a coming or going fault on the CAN
bus communication.
Depending on the communication bus side, the logged source can be the control unit or a single sensor.
9.6.2 CAN errors (CANERROR)
Error Meaning
TIMEOUT Timeout on message to sensor/control unit
CROSS CHECK Two redundant messages do not coincide
SEQUENCE NUMBER Message with sequence number different from the expected number
CRC CHECK Packet control code does not match
COMMUNICATION
LOST
Impossible to communicate with the sensor
PROTOCOL ERROR Control unit and sensors have different and incompatible firmware versions
POLLING TIMEOUT Timeout on data polling
NOTICE: A shielded cable between the control unit and the first sensor, and between the sensors is strongly
recommended. Nevertheless, route the CAN cables separately from high-potential power lines or through an
exclusive conduit.