98
Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
9. Troubleshooting
Error Meaning
SEQUENCE,
STREAM
SEQUENCE,
STREAM END,
STREAM CRC
Sequence error occurred during the sensor configuration
MISSING SENSORS Too many sensors are missing during the system recondition
9.5.3 Misconfiguration error (MISCONFIGURATION ERROR)
The misconfiguration error occurs when the sensor does not have a valid configuration or it has received an
invalid configuration from the control unit.
9.5.4 Status error and fault (STATUS ERROR/FAULT ERROR)
The status error occurs when the sensor is in an internal invalid status or it has reached an internal fault
condition.
9.5.5 Protocol error (PROTOCOL ERROR)
The protocol error occurs when the sensor receives commands with an unknown format.
9.5.6 Sensor voltage errors (POWERERROR)
Error Meaning
Sensor voltage
UNDERVOLTAGE
Undervoltage error for the indicated voltage
Sensor voltage
OVERVOLTAGE
Overvoltage error for the indicated voltage
The following table describes the sensor voltage:
Screen printing Description
VIN Power supply voltage (+12 V DC)
V3.3 Internal chip power supply voltage
V1.2 Micro-controller power supply voltage
V1.8 Internal chip power supply voltage (1.8 V)
V1 Internal chip power supply voltage (1 V)
9.5.7 Anti-tampering sensor (TAMPERERROR)
Error Meaning
TILTANGLEERROR Sensor rotation around the x-axis
ROLLANGLE ERROR Sensor rotation around the z-axis
PANANGLE ERROR Sensor rotation around the y-axis
Note: the information of the angle (in degrees) is reported.
9.5.8 Signal error (SIGNALERROR)
The signal error occurs when the sensor detected an error in the RF signals part, in particular:
Error Meaning
MASKING The sensor is obstructed
MASKINGREFERENCEMISSING During the configuration process, it was not possible to get the masking
reference
SIGNALPATTERNERROR Radar internal fault or unexpected signal pattern