10.2.4 Back up the configuration to a PC
The current configuration can be backed up, including the input/output settings. The configuration is saved in a
.cfg file, which can be used to restore the configuration or to facilitate configuration of several Inxpect SRE 200
Series.
1. In Settings > General, click BACKUP.
2. Select the file destination and save.
Note: user login credentials are not saved using this backup mode.
10.2.5 Back up the configuration to a microSD card
If the control unit is provided with a microSD slot, a backup file of the system settings, and (optionally) the login
credentials of all the users, can be stored on the microSD card. The SD Backup function can be enabled/disabled
through the Inxpect Safety application, as well as the backup of the login credentials of all the users. By default,
both options are disabled.
1. To enable the SD Backup function, in Admin > SD Card select Automatic backup creation.
2. To enable the saving of all users' login credentials, select Users data included.
3. To perform the backup, insert a microSD card into the control unit memory card slot.
Note: the microSD card is not supplied with the control unit. For details about the microSD card
specifications, see "microSD card specifications" below
4. In the Inxpect Safety application, click APPLY CHANGES: the backup is automatically performed.
10.2.6 Load a configuration from a PC
1. In Settings > General, click RESTORE.
2. Select the previously saved .cfg file (see "Back up the configuration to a PC" above) and open it.
Note: a re-imported configuration requires new downloading onto the control unit and approval according
to the safety plan.
10.2.7 Load a configuration from a microSD card
If the control unit is provided with a microSD slot, the administrator can restore both the system settings and (if
any) the login credentials of all the users. This requires a valid backup file saved on a microSD. The SD Restore
function can be enabled/disabled through the Inxpect Safety application. By default the option is enabled.
Note: this SDRestore function also includes a System recondition operation, see "Replace a sensor: System
recondition function" on the previous page.
1. To perform the restore, insert the microSD card with the saved configuration into the memory card slot
of the new control unit.
Note: the microSD card is not supplied with the control unit. For details about the microSD card
specifications, see "microSD card specifications" below
2. Press the SD Restore button on the control unit: the restore is performed.
Note: to disable the SD Restore function, in Admin > SD Card deselect Enable restore by button
The following actions are performed:
l
The system configuration is applied (APPLY CHANGES operation).
l
The event is logged in the reports archive (Settings > Activity History > Configuration reports page) with
the string Restore-via-sdcard.
10.2.8 microSD card specifications
Type microSD
File system FAT32
Recommended capacity 32 GB or less
10. Maintenance
Inxpect SRE 200 Series | Instruction manual v1.5 DEC 2023|Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
103

Table of Contents