Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
9. Troubleshooting
Event Type
MODBUS connection INFO
Session authentication INFO
Validation INFO
Log download INFO
For further information about the events, see "INFOevents" on the next page and " ERRORevents (control unit)"
on page95.
9.2.10 Verbosity level
There are six verbosity levels for the log. The verbosity can be set during the configuration of the system via the
Inxpect Safety application (Settings > Activity History > Log verbosity level).
Depending on the selected verbosity level, the events are logged in accordance to the following table:
Event
Level 0
(default)
Level 1 Level 2 Level 3 Level 4 Level 5
Diagnostic errors x x x x x x
System Boot
x x x x x
x
System configuration
x x x x x
x
Factory reset x x x x x x
Stop signal
x x x x x
x
Restart signal
x x x x x
x
Detection access - See "Verbosity level for detection access and exit events"
below
Detection exit - See "Verbosity level for detection access and exit events"
below
Dynamic configuration in
use
- - - - x x
Muting status - - - - - x
9.2.11 Verbosity level for detection access and exit events
Depending on the selected verbosity level, the detection access and exit events are logged as follows:
l
LEVEL0: no detection info is logged
l
LEVEL 1: the events are logged at the control unit level, and the additional information is the detection
distance (in mm) and the detection angle (in °) in detection access
Format:
CONTROLUNIT Detection access (distance mm/azimuth°)
CONTROLUNIT Detection exit
l
LEVEL 2: the events are logged in a single field at the control unit level, and the additional information is:
detection field, detection distance (in mm) and detection angle (in °) in access, and detection field at exit
Format:
CONTROLUNIT Detection access (field #n, distance mm/azimuth°)
CONTROLUNIT Detection exit (field #n)
l
LEVEL 3 / LEVEL 4 / LEVEL 5 The events are logged:
o
in a single field at the control unit level, and the additional information is: detection field, detection
distance (in mm) and detection angle (in °) in access, and detection field at exit
o
at the sensor level and the additional information read by the sensor is: detection distance (in mm) and
detection angle (in °) in access, and detection field at exit
Format:
CONTROLUNIT #k Detection access (field #n, distance mm/azimuth°)
SENSOR #k Detection access (distance mm/azimuth°)