3.1.3 Main components
Inxpect SRE 200 Series is composed of a control unit and up to six sensors. The Inxpect Safety application allows
system operation configuration and checks.
3.1.4 Control unit and sensor compatibility
The models and types of control unit and sensors are shown below, with their compatibility.
Each control unit, updated to firmware version 2.0.0, can communicate with any sensor.
NOTICE: do not connect the control unit with other types of sensors (e.g., 9 meters range sensors).
The control unit can be simultaneously connected to both 3.x sensors and 5.x sensors. For more details about the
available features, see " Sensors" on page26.
3.1.5 Control unit - sensor communication
The sensors communicate with the control unit via CAN bus using diagnostic mechanisms in compliance with
standard EN 50325-5 to guarantee SIL 2 and PL d.
For correct functioning, each sensor must be assigned an identification number (Node ID).
Sensors on the same bus must have different Node IDs. By default, the sensor does not have a pre-assigned
Node ID.
3. Get to know Inxpect SRE 200 Series
Inxpect SRE 200 Series | Instruction manual v1.5 DEC 2023|Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
15