Battery Simulation Function
Copyright © Itech Electronic Co., Ltd. 63
9. The screen prompts “Saved!”, and the external data are successively
saved.
Note
For IT6411/IT6431/IT6432/IT6433/IT6411S/IT6432S power supply, the battery
characteristic data file needs to be named Battery.csv.
Recall the battery characteristic data group.
If several battery characteristic data groups are edited, the User may select the
ones to be recalled. Operating procedures are as below:
1. On the Battery Simulation Function interface, press the right [Channel 1/2]
soft key to select configuring channel CH2. (Only IT6402/IT6412/IT6412S
contain this step.)
2. Press the [Mode] soft key to select test mode Simulator, and press the [OK]
key for confirmation.
3. Press the [Recall] soft key to enter the Data Group Recall interface.
4. Configure Group number. By the , move the cursor to the Group
setting place and press the Numeric key or Knob to set the number value of
the data group to be recalled. Press the [OK] key for confirmation. At this
time, the characteristic data display area displays the characteristic data of
each step in this group.
⚫ IT6411/IT6431/IT6432/IT6433/IT6411S/IT6432S
⚫ IT6402/IT6412/IT6412S