Before the charge
Before starting the baery charge it is necessary to check the elec-
trolyte level and, if necessary, ll up till all elements are completely
covered.
•Open the boxes.
•Open the electrolyte lling caps.
•Check the level and if necessary ll up with distilled water.
•Close the caps and wipe away the liquid that might have come out.
The sulphuric acid in the solution can cause serious injuries; in case
it is unintentionally spilt, wash objects and surfaces with plenty of
water.
If the acid comes into contact with skin or eyes, wash immediately
with plenty of water and consult a doctor.
It is recommended to always wear protective gloves and glasses
during baery servicing
Charge start
The recharge has to be carried out in a suitable room, well ventilated
and separate from the working room, because baeries generates
inammable gases, which can cause explosions if they come into
contact with ames or sparks.
The recharge has to be carried out with open boxes.
By connecting a main cable to the upper back outlet, the baery charger
is automatically started aer a few seconds;