EasyManua.ls Logo

iteco IT 10151 - Before the Charge; Charge Start

Default Icon
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
IT10151 - IT12151
OPERATING AND MAINTENANCE HANDBOOK
Before the charge
Before starting the baery charge it is necessary to check the elec-
trolyte level and, if necessary, ll up till all elements are completely
covered.
•Open the boxes.
•Open the electrolyte lling caps.
•Check the level and if necessary ll up with distilled water.
•Close the caps and wipe away the liquid that might have come out.
The sulphuric acid in the solution can cause serious injuries; in case
it is unintentionally spilt, wash objects and surfaces with plenty of
water.
If the acid comes into contact with skin or eyes, wash immediately
with plenty of water and consult a doctor.
It is recommended to always wear protective gloves and glasses
during baery servicing
Charge start
The recharge has to be carried out in a suitable room, well ventilated
and separate from the working room, because baeries generates
inammable gases, which can cause explosions if they come into
contact with ames or sparks.
The recharge has to be carried out with open boxes.
By connecting a main cable to the upper back outlet, the baery charger
is automatically started aer a few seconds;