IT10151 - IT12151
OPERATING AND MAINTENANCE HANDBOOK
Electrolyte level check
•Open the box
•Take away the electrolyte supplying caps
•Check the level and if it is the case top up with distilled water.
•Close caps and dry if some liquid has poured out.
The sulphuric acid contained in the solution could cause serious in-
juries; if it is unintentionally poured , wash immediately the objects
or the surfaces with abundant water.
If the acid comes into contact with skin or eyes wash immediately
and generously with water and seek a doctor.
It is recommended to always wear gloves and protective glasses
during the maintenance operations of baeries. Check of screw
tightening.
Check of baery charge
The baery charge level can be read on ground panel.
For the baery recharge see section “Baery recharge”.