75
IT10151 - IT12151
OPERATING AND MAINTENANCE HANDBOOK
Grease the mechanisms
Two lubricators are placed above back wheel spindles.
Safety check
The following test enables to check that all safety devices of the ma-
chine work properly.
The safety systems applied to the machine are inevitably subject to wear
and to go out of tune. Therefore, they must be controlled and kept in
perfect eciency; also, it is not advisable to evaluate their operational
and safety conditions only on the basis of their functioning.
The presence of safety systems does not relieve the operator of the re-
sponsibility of using the machine in an adequate and conscious way.
Red emergency stop push buon
•Press emergency stop push buon on ground control panel and check
that no operation is possible, either from ground or on platform. Put
push buon to ON again.
• Press emergency stop push buon on platform control panel and
check that no operation is possible, either from ground or on platform.
Put pu h-buon to ON again.
SQ1 Microswitch
Safety speed
Make sure that there are no obstacles above or under platform, before
executing this test.
•Li platform above microswitch SQ1 operating height from platform
control panel.
•Check that drive is possible at safety speed only.