66
IT10151 - IT12151
OPERATING AND MAINTENANCE HANDBOOK
Optional
110V line
To supply current in platform it is necessay to connect a mains cable
to the lower back plug.
A socket foreseen in the platform supplies current to electric instru-
ments.
A cut-out box switch and a magnetothermic switch have also been
provided in the le back box.
Baery charger kit 110V
This kit includes all elements to recharge the baeries at 110 V.
Features
•Baery charger: 48V - 40A
•Power supply: 115V single-phase - 50÷60 Hz
•Voltage: 48V
•Charge time: about 10 hours
•Operating temperature: from -20°C to +50°C
•Protection against output short circuit
•Protection against polarity reversal (fuse)
•Weight: 5,5 Kg
•Connection to the net: standard 3 poles 115V outlet