Chapter 7 Test Results
Frame relay results
96 SmartClass E1 Tester User’s Guide
Clock results
See “Clock results” on page 91.
Control Signal
See “Control Signal results” on page 91.
Data Results
See “Data results” on page 92.
DLCI results
Table 30 lists results in the DLCI (Data Link Connection Identifier) category.
These results apply to the DLCI you specified as a frame header setting when
you configured your test.
Rx Error Bipolar Tim-
ing Count
Number of detected bipolar timing errors. (G703 inter-
face only)
Rx Error Bipolar Tim-
ing Present
Bipolar timing errors have been detected. (G703 inter-
face only)
Rx Clock Present Receiver clock detected. Only appears if using synchro-
nous timing.
Rx Clock History Receiver clock detected since last test restart.
Tx Clock Present Transmitter clock detected. Only appears if using syn-
chronous timing.
Tx Clock History Transmitter clock detected since last test restart.
Ex Clock Present External clock detected. Only appears if using synchro-
nous timing. (G703 interface only)
Ex Clock History External clock detected since last test restart. (G703
interface only)
Rx Overrun Receiver overflow.
Oob Flow Ctrl Status Indicates whether out-of-band (Oob) flow control is on or
off.
Table 29 Summary results (Continued)
Result Definition
Table 30 DLCI results
Result Definition
Frm Cnt Rx Count of the total number of frame relay frames
detected.
Frm Octets Rx Count of the total number of frame relay octets
detected.
Avg Frm Size Rx Calculates the average size of received frames (frame
octets ÷ frame count).
Avg Frm Rate Rx The average number of frame relay frames received
per second, since the start of the test (frame count ÷
total seconds).
Max Frm Rate Rx The maximum number of frame relay frames received
per second, since the start of the test.