Chapter 1 Getting Started
Exploring the front panel
SmartClass E1 Tester User’s Guide 7
Status LEDs
These indicators report the status of the unit. The function of the LEDs change
depending on the application. Table 6 describes each of the Status LEDs.
Table 6 Status LEDs
Status LED Description
Sync For E1 testing:
Green
Solid—A signal is present and synchronization is established
on all active receivers.
Flashing—Auto-framing is running on at least one active
receiver.
Red
At least one of the active receivers does not have frame syn-
chronization.
Off
No signal has been detected on any receiver.
For Datacom testing:
Green
Solid—A receive clock is present.
Red
Solid—A receive clock was present at some point in the past,
but was lost.
Off
No receive clock has been detected on any receiver.
Data/LpBK Green
Solid—Synchronization is established with BERT pattern for all
active receivers.
Flashing—Auto-pattern is running on at least one active
receiver.
Red
At least one of the active receivers does not have pattern syn-
chronization.
Amber
For E1 testing: The E1 Tester has been placed in a line loop-
back mode.
Off
The E1 Tester is not in a line loopback mode, which means the
selected traffic pattern is live on all active receivers, or no pat-
tern synchronization has been detected on the receiver.
Err/Alm Red
FlashingThe LED flashes for one second when an error or
alarm occurs. Or, for E1 testing, flashes when the unit is
searching for framing or a pattern during Auto Config.
Amber
At least one error or alarm has occurred since that last reset.
Off
All Summary results are OK. No error or alarm has been
received.

Table of Contents