Chapter 4 E1 Testing
Testing MFC-R2 Signaling
46 SmartClass E1 Tester User’s Guide
Testing MFC-R2 Signaling
The SmartClass E1’s MFC-R2 signaling option allows testing of line signaling
(supervisory signals) and inter-register signaling (call control signals).
This test involves three basic steps:
Configuring test settings
Connecting to the circuit
Running the test
Configuring test settings
Before running any tests, you should configure the E1 Tester with the appro-
priate settings for the line under test.
To configure test settings
1 From the E1 Measurement menu, launch the E1 R2 application.
2 From the E1 R2 menu, select Configuration.
The Configuration menu appears.
3 Specify values for the Test Mode and Country, as described below:
4 Select Interface, and then specify the values as described below:
NOTE:
MFC-R2 Signaling is an optional feature. It only appears if you have pur-
chased the MFC-R2 software option.
Setting Parameter
Test Mode Select one of the following:
Simulate
–Monitor
Bridge (HI-Z)
Country Select one of the following:
–ITU-T
Mexico
Brazil
Brazil (San Paolo)
–India
Philippines
China
–User Defined
Setting Parameter
Line Code Select one of the following line coding
options:
HDB3: High Density Bipolar 3
AMI: Alternate mark inversion