Chapter 4 E1 Testing
Testing MFC-R2 Signaling
SmartClass E1 Tester User’s Guide 47
5 From the Configuration menu, select Simulate Settings, and then specify
the values as described below:
Clock Source
(selectable only in Simulate
test mode)
Select one of the following:
– Internal
– Rx1
– Rx2
– Ext. BNC
NOTE: If timing is lost, the SmartClass reverts
to internal timing.
Framing Select one of the following:
– PCM30C
– PCM30
MF Channel Select the MF channel or channels.
– To turn on the selected channels, use the
arrow keys to point at the channels/
timeslots you want to turn on, and then
press the # key to select it.
– If in Monitor/Bridge mode, you can select
multiple channels.
– If in Simulate mode, select only one chan-
nel.
When you have finished selecting channels,
press OK.
Idle Code
(selectable only in Simulate
test mode)
Enter an 8-bit binary string
Setting Parameter
Sequence Generation Select one of the following:
– Express
– Advanced
Direction Select one of the following:
– Forward
– Backward
DID Number
(selectable only for Forward
Direction and Express
Sequence Generation)
Enter the Direct Inward Dial (DID) number.
This is the phone number to be called.
ANI Number
(selectable only for Forward
Direction and Express
Sequence Generation)
Enter the Automatic Number Identification
(ANI) number. This is the caller's number, typ-
ically the E1Tester’s own number.
Category
(selectable only for Forward
Direction and Express
Sequence Generation)
Select a category. This is the E1Tester’s own
category, from II-1 to II-15.
Number of DIDs
(selectable only for Back-
ward Direction and Express
Sequence Generation)
Specify the number of DIDs on the circuit.
Setting Parameter