Chapter 4 E1 Testing
Testing MFC-R2 Signaling
48 SmartClass E1 Tester User’s Guide
6 Select User Defined Settings, and then specify the values as described
below. These settings are only definable if the Country is set to “User
Defined”.
7 Optional. To save the test configuration, Save/Restore-View. For more
information on saving test configurations, see “Managing test configura-
tions” on page 24.
The settings are specified
Number of ANIs
(selectable only for Back-
ward Direction and Express
Sequence Generation)
Specify the number of ANIs on the circuit.
Final Status
(selectable only for Back-
ward Direction and Express
Sequence Generation)
Select the Final Status signal, between and
B-1 and B-15.
Clear First Select which end should be cleared first:
–Home
– Opposite End
User Defined Signalings
(selectable only with
Advanced Sequence Gener-
ation)
Enter a signal between 1 and 30.
Delay Btwn. Signals Specify the time to wait (delay) between sig-
nals.
Pause Before Dial/Answer Specify whether to pause before dialing or
answering.
Setting Parameter
ANI Calling Party Category Select a category. This is the E1Tester’s own
category, from II-1 to II-15.
ANI Category Select a category. This is the E1Tester’s own
category, from II-1 to II-15.
ANI Category Req. Tone Select a tone, from A1 to A15
ANI Request Type Select one of the following:
– Do not request ANI
– After first DNIS Digit (default)
– After second DNIS Digit
– After complete DNIS
ANI Tone Request Select a tone, from A1 to A15
Answer Tone Select a tone, from A1 to A15
DNIS Tone Request Select a tone, from A1 to A15
CD Bits Specify the CD bits.
GroupB Rcv Busy Tone Select a timeslot between 0 and 15.
GroupB Rcv Idle Tone Select a timeslot between 0 and 15.
Setting Parameter