EasyManua.ls Logo

JDS Uniphase SmartClass E1 - Specifying Polarity Settings; Specifying a BERT Pattern

JDS Uniphase SmartClass E1
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Datacom Testing
Specifying test settings
SmartClass E1 Tester User’s Guide 55
Specifying polarity settings
The following procedure describes how to configure clock and data polarity
settings.
To specify polarity settings
1 If you haven’t already done so, launch the Data Communication applica-
tion (see “Launching the datacom application” on page 52).
2 On the Configuration menu, select Polarity, and then specify values for
the following settings:
You have finished specifying the polarity settings.
Specifying a BERT pattern
You can specify a specific BERT pattern for your test.
To specify a BERT pattern
1 If you haven’t already done so, launch the Data Communication applica-
tion (see “Launching the datacom application” on page 52).
2 On the Configuration menu, select BERT Pattern Settings, and then
choose a pattern:
Setting Parameter
RxClock Polarity Specify the polarity for the Rx Clock:
Normal. Uses the phasing specified by the inter-
face standard.
Inverted. Uses the inverse of the phasing specified
by the interface standard.
TxClock Polarity Specify the polarity for the Tx Clock:
Normal. Uses the phasing specified by the inter-
face standard.
Inverted. Uses the inverse of the phasing specified
by the interface standard.
RxData Polarity Specify the polarity for the received data:
Normal. Uses the phasing specified by the inter-
face standard.
Inverted. Uses the inverse of the phasing specified
by the interface standard.
TxData Polarity Specify the polarity for the transmitted data:
Normal. Uses the phasing specified by the inter-
face standard.
Inverted. Uses the inverse of the phasing specified
by the interface standard.
Pattern Description
PRBS 63 Selects the 2
6
-1 pseudorandom pattern, which
generates a maximum of 5 sequential 0s and 6
sequential 1s.
PRBS 511 Selects the 2
9
-1 pseudorandom pattern, which
generates a maximum of 8 sequential 0s and 9
sequential 1s.

Table of Contents

Other manuals for JDS Uniphase SmartClass E1

Related product manuals