IFC-3030 Installation Manual — P/N 52024:C 08/05/2005 51
NFPA 72 Proprietary Fire Alarm Systems Applications
4.4 NFPA 72 Proprietary Fire Alarm Systems
When connected and configured as a protected premises unit with monitor and relay modules, the
IFC-3030 will automatically transmit General Alarm, General Trouble, General Supervisory, and
Security signals to a listed compatible Protected Premises Receiving Unit. A simplified drawing of
connections between the receiving unit and the IFC-3030 protected premises unit is shown in
Figure 4.3.
Connect the receiving unit to the protected premises unit as shown in Section 4.3 “NFPA 72
Central or Remote Station Fire Alarm System (Protected Premises Unit)”.
Install and program the Receiving unit with type codes and zone mappings shown in Figure 4.3; see
the programming manual for procedures.
8
9
10
11
12
13
14
150
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
TENS
ONES
LOOPLOOP ADDRESS
ADDRESS
8
9
7
6
5
9
8
7
6
5
0
1
2
3
4
4
3
2
1
0
TENS
ONES
8
9
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
150
1
2
3
4
5
6
7
8
9
10
11
12
13
14
150
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
TENS
ONES
LOOPLOOP
A
DDRESS
A
DDRESS
8
9
7
6
5
9
8
7
6
5
0
1
2
3
4
4
3
2
1
0
TENS
ONES
8
9
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
150
1
2
3
4
5
6
7
Receiving Unit
Compatible With IFC-3030
SLC Loop
(twisted-pair
wiring)
SLC Loop
(twisted-pair
wiring)
3030-Rcvg-blok.cdr
Monitor Modules Relay Modules
Type code: Security-L
Type code: Trouble Mon
Type code: Monitor
Type code: Relay
Zone mapping: ZF03
Type code: Relay
Zone mapping: ZF04
Type code: Relay
Zone mapping:
ZF01 & ZF02
Type code: Relay
Zone mapping: Z000
Type code: Superv
IFC-3030
Protected Premises Unit
Monitor Module
PPU SLC Loop IN
PPU SLC
Loop OUT
Receiving Unit
SLC Loop OUT
Detail View
Receiving Unit
SLC Loop IN
Relay Module
Block View
3030-Rcvg-wir.cdr
ELR-47K
PRN series
printer
Note: Remote printers require 120 VAC, 50/60Hz primary power. A secondary power source (battery backup) is not provided; the use
of a separate Uninterruptable Power Supply (UPS) 50 watt minimum, UL-listed for Fire Protective Signaling is recommended. A UPS
is required for NFPA 72-1999 Proprietary Protected Premises Receiving Unit Applications.
UPS
Figure 4.3 Typical Proprietary Fire Alarm Systems Wiring Connections

Table of Contents

Other manuals for Johnson Controls IFC-3030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls IFC-3030 and is the answer not in the manual?

Johnson Controls IFC-3030 Specifications

General IconGeneral
BrandJohnson Controls
ModelIFC-3030
CategoryControl Panel
LanguageEnglish

Related product manuals