95
XP7202 Instruction Manual
Fail-Safe
The Fail-Safe/Hold Function is available only when  
you use PCM modulations (see modulation page 77) 
Durning loss of signal this function drives the servos to 
either the fail-safe preset positions or hold the last signal 
position. As noted, if you are in the PPM modulation, the 
Fail-Safe/Hold Function is not applicable. Therefore, the 
Fail-Safe/Hold Function will not appear on your LCD in 
PPM mode. Refer to the Modulation Selection Section for 
more information.
Accessing the Fail-Safe Function
Press the Down and Select keys simultaneously to 
access the Function Mode
In Function Mode, use the UP or Down keys to select 
the FAIL SAFE screen.
Press the Select key to highlight the desired channel
Press the IncreaSe or DecreaSe keys to select 
FAILSAFE (the servo goes to a preset programmed 
position during signal loss) or HOLD (the servo holds last 
position during signal loss. 
With the sticks and switches in the desired fail safe 
positions, press the clear key to store these failsafe 
position in memory.
NOTE
: To test the fail-safe turn the transmitter off. 
Any channel that is set to a fail-safe position should 
drive to that position and any servo that is set to hold 
should remain in it’s last good position.