KACO blueplanet 3.0 NX3 M2 KACO blueplanet 5.0 NX3 M2 KACO blueplanet 8.0 NX3 M2 KACO blueplanet 10.0 NX3 M2
KACO blueplanet 15.0 NX3 M2 KACO blueplanet 20.0 NX3 M2 Page 3
Contents
1 Installation .......................................................... 4
1.1 Safety ........................................................................... 4
1.2 Scope of delivery..................................................... 4
1.3 Choosing the installation location ................... 5
1.4 Mounting the wall bracket .................................. 6
1.5 Installing the device ............................................... 6
1.6 Making the electrical connection ..................... 7
1.6.1 General view inverter from the bottom ......... 7
1.6.2 Configure AC connection .................................... 8
1.6.3 Configuring the DC connection ........................ 8
1.7 Creating equipotential bonding ....................... 9
1.8 Connecting the WLAN module ....................... 10
1.9 RS485 connection ................................................. 10
2 Commissioning ................................................. 11
3 Maintenance and troubleshooting ................ 11
3.1 Visual inspection ................................................... 11
3.2 Cleaning ................................................................... 11
3.2.1 Cleaning the housing and the heat sink ...... 11
4 Decommissioning and dismantling ............... 12
4.1 Switching off the device .................................... 12
4.2 Uninstalling the device ...................................... 12
4.3 Disassembling the device ................................. 12
5 Disposal ............................................................. 12
1 EN - Contents
Legal provisions
The information contained in this document is the property of KACO new energy GmbH. Publication, in whole or in part,
requires the written permission of KACO new energy GmbH.
KACO warranty
For current warranty conditions contact your system integrator. http://www.kaco-newenergy.com
Trademarks
All trademarks are recognised, even if not explicitly identified as such. A lack of identification does not mean that a product
or designation/logo is free of trademarks.
Software
This device contains open source software developed by third parties and in some cases licensed under GPL and/or LGPL.

Table of Contents

Other manuals for Kaco blueplanet 10.0 NX3 M2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaco blueplanet 10.0 NX3 M2 and is the answer not in the manual?

Kaco blueplanet 10.0 NX3 M2 Specifications

General IconGeneral
Modelblueplanet 10.0 NX3 M2
ManufacturerKaco
CategoryInverter
Max. AC Output Power10000 W
Max. DC Voltage1100 V
Number of MPPTs2
Max. apparent AC power10000 VA
AC frequency50 Hz / 60 Hz
Max. AC current16 A
Max. DC current26 A
Protection classIP65
TopologyTransformerless
Operating Temperature Range-25°C to +60°C
CoolingConvection
Max. DC power15000 W
AC Output Voltage230 V / 400 V
AC voltage range230 V / 400 V