station, but there will be no data sent to you from that connection. The connected
data would be sent to the serial port of that remote TNC. We urge EXTREME
caution when using the remote access! Note also that any command that causes a
reset (i.e. NUMNODES, PBBS, MAXUSERS) will disconnect all current users
(PBBS, NODE, and YOU).
One other minor limitation applies to receiving data from the remote TNC. When
you give any command, the response is limited to 300 characters so some com
-
mands will not fully display their response. If you give the command DISPLAY,
the full list will begin, but you will not receive the entire list because of the limi
-
tation on this buffer.
+
To disconnect from a MYREMOTE station, issue a standard disconnect for the
station you are operating: press Ctrl+C and Enter to get to the command line
(where you will see “Cmd:”), then press D and Enter, to disconnect.
Remote Access to Your TNC Packet Modes of Operation
KAM’98 v 8.3 159 User’s Guide