SPACE n (n = 50 - 4000)
default 2295
This command sets the space frequency. The SPACE command must be set
greater than the MARK command.
+
For 1200 baud Packet operation, change SPACE to 2100.
Note: When switching from 300 baud packet operation on HF to 1200 baud packet
operation on VHF/UHF, remember to change the following (HF defaulted) parame
-
ters: Mark, Space, SWP, Slottime, Persist, Maxframe, Paclen, Hbaud. See the
packet section in the modes of operation chapter for further detail (page 144).
+ Note: The TNC spedifications are for SPACE values from 50 through 2400.
Higher values (to 4000) are for experimental use.
See also: mark, shift.
START n (n = $00 - $FF)
default $11 <Ctrl+Q>
This command specifies the character sent by the computer to the TNC to restart
output from the TNC. If set to $00 only hardware flow control will be used. For
software flow control, set this parameter to the character the computer will send
to restart data flow.
See also: stop, xflow, xoff, xon
#
STATUS [LONG]
immediate
Entry of the STATUS command will display the number of bytes available
(i.e., free bytes) in the RS232 input buffer, the current I/O stream ,and any
streams having a connected status.
KAM’98 Commands Command Reference
KAM’98 v 8.3 307 User’s Guide