software flow control set this parameter to the character the computer expects to
see to stop sending data to the TNC.
See also: xflow, xon
XON n (n = $00 - $FF)
default $11 <Ctrl+Q>
This command selects the character sent by the TNC to the computer to restart
input from that device. If set to $00 hardware flow control must be used. For
software flow control set this parameter to the character the computer expects to
see to restart sending data to the TNC.
See also: xflow, xoff