3.1.2 Mechanical environmental conditions
Storage Standard Class Notes
Vibration limits EN 60721-3-1 1M2
Vibration amplitude 1.5 mm (2…9 Hz)
Acceleration amplitude 5 m/s² (9…200 Hz)
Shock limit values EN 60721-3-1 1M2 40 m/s²; 22 ms
Transport Standard Class Notes
Vibration limits EN 60721-3-3 2M1
Vibration amplitude 3.5 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
(Acceleration amplitude 15 m/s² (200…500 Hz))
1)
Shock limit values EN 60721-3-2 2M1 100 m/s²; 11 ms
Operation Standard Class Notes
Vibration limits EN 60721-3-3 3M4
Vibration amplitude 0.3 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
Shock limit values EN 60721-3-3 3M4 100 m/s²; 11 ms
Table 2: Mechanical environmental conditions
1)
Not tested.
3.1.3 Chemical/mechanical active substances
Storage Standard Class Notes
Contamination
Gases
EN 60721-3-1
1C2
Solids 1S2
Transport Standard Class Notes
Contamination
Gases
EN 60721-3-2
2C2
Solids 2S2
Operation Standard Class Notes
Contamination
Gases
EN 60721-3-3
3C2
Solids 3S2
Table 3: Chemical/mechanical active substances
3.1.4 Electrical operating conditions
3.1.4.1 Deviceclassication
Requirement Standard Class Notes
Pollution degree EN 60664-1 2
Non-conductive pollution, occasional condensa-
tion when PDS is out of service.
Table 4: Device classication
17
OPERATING CONDITIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBILINE Z2 Series and is the answer not in the manual?

KEB COMBILINE Z2 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBILINE Z2 Series
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals