3.2.5 Technical data of the cable sets
Cupal washers must be used between the aluminium connection and the copper line at
the capacitor connection => „Connecting example for capacitor modules with M12 screw
connection“.
Material number
Cable lengths
in mm
Conductor
cross-section in
mm²
Conductor connection
Max. current
per conductor
in A
00Z2T09-0002 3 x 300 1.5 Wire-end ferrule 1.5 mm² 26
00Z2T09-0010
3 x 1000
10 Ring crimp connector M12 80
00Z2T09-1010 10
Ring crimp
connector
M12
Ring crimp
connector
M10
80
00Z2T09-2010 10
Ring crimp
connector
M12
Wire-end fer-
rule 10 mm²
80
00Z2T09-0025 25 Ring crimp connector M12 140
00Z2T09-1025 25 Ring crimp
connector
M12
Ring crimp
connector
M10
140
00Z2T09-1035
35
00Z2T09-0035
Ring crimp connector M12
174
00Z2T09-0070 70 273
00Z2T09-0095 95 334
Table 9: Technical data of the cable sets