Para. Name E R Res. Lower
Limit
Upper
Limit
Default Unit
LF.41 Leveling Speed E R/W 0.1 0 25 0 ft/min
LF.42 High Speed E R/W 0.1 0 LF.20 0 ft/min
LF.43 Inspection Speed E R/W 0.1 0 150 0 ft/min
LF.44 High Leveling Speed E R/W 0.1 0 25% of LF20 0 ft/min
LF.45 Intermediate Speed 1 E R/W 0.1 0 100% of LF20 0 ft/min
LF.46 Intermediate Speed 2 E R/W 0.1 0 100% of LF20 0 ft/min
LF.47 Intermediate Speed 3 E R/W 0.1 0 100% of LF20 0 ft/min
LF.50 Starting Jerk E R/W 0.01 0.3 32.00: off 3.0 ft/s
3
LF.51 Acceleration E R/W 0.01 0.3 12.00: off 3.3 ft/s
2
LF.52 Acceleration Jerk E R/W 0.01 0.3 32.00: off 4.0 ft/s
3
LF.53 Deceleration Jerk E R/W 0.01 0.3 32.00: off 4.5 ft/s
3
LF.54 Deceleration E R/W 0.01 0.3 12.00: off 3.5 ft/s
2
LF.55 Aproach Jerk E R/W 0.01 0.3 32.00: off 2.5 ft/s
3
LF.56 Stop Jerk E R/W 0.01 0.3 32.00: off 2.0 ft/s
3
LF.57 Speed Following Error E R/W 1 0 2 1 text
LF.58 Speed Difference E R/W 1 0 30 10 %
LF.59 Following Error Timer E R/W 0.1 0 1 1 sec
LF.61 Emergency Operation Mode E R/W 1 0 4 0 text
LF.67 Pretorque Gain E R/W 0.01 0.25 2 1 -
LF.68 Pretorque Offset E R/W 0.1 -100 100 0 %
LF.69 Pretorque Direction E R/W 1 -1 1 1 -
LF.70 Speed Start Delay E R/W 0.1 0 3 0.3 s
LF.71 Brake Release Delay E R/W 0.1 0 100 0.05 s
LF.76 Encoder Resolution Multiplier E R/W 1 0 13 2 -
LF.77 Absolute Encoder Position E R/W 1 0 65535 1000 -
LF.78 Brake Engage Time E R/W 0.01 0 3 0.5 s
LF.79 Current Hold Time E R/W 0.1 0.1 0.5 0.3 s
LF.80 Software Version R -
LF.81 Software Date R -
LF.82 X2-Input State R Table -
LF.83 X2-Output State R Table -
LF.86 Selected Speed R 1 0 7 -
LF.87 Inverter Load R 1 %
LF.88 Motor Command Speed R 0.1 rpm
LF.89 Actual Motor Speed R 0.1 rpm
LF.90 Actual Elevator Speed R 1 ft/min
LF.93 Phase Current R 0.1 A
LF.94 Peak Phase Current R 0.1 A
LF.95 DC Bus Voltage R 1 V
LF.96 Peak DC Bus Votlage R 1 V
LF97 Actual Output Frequency R 0.1 Hz
LF98 Last Fault R Table
LF.99 Inverter State R Table
Parameter List Reference

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals