87
Binary speed setting uses preset digital values in the drive as com-
mand speeds. The drive creates the driving pro le between selected
speeds. The inputs are binary coded to allow up to seven speeds.
Additionally in this mode, more advanced and multiple pro les can
be established. See parameters LF.41...LF.56. One speed can be
pre-de ned as an emergency run speed in which the drive operates
automatically under emergency operation conditions. See parameter
LF.61 for more details.
f) Binary coded set speed selection LF.02 = bnSPd
Parameter Description - Basic Set Up
Symbol: 1 = Input is active
0 = Input is not active
X = Setting has no effect or don’t care
X2A.10 X2A.11 X2A.12 X2A.13 Para.
Speed =0 x 0 0 0
S
Leveling
x 1 0 0 LF.41
S
High Leveling
x 0 1 0 LF.44
S
Inspection
x 1 1 0 LF.43
S
High
x 0 0 1 LF.42
S
Intermediate_1
x 1 0 1 LF.45
S
Intermediate_2
x 0 1 1 LF.46
S
Intermediate_3
x 1 1 1 LF.47

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals