Display values:
Start session
A Charging Session has started.
Resume session
A charging session has been resumed by the Electric Vehicle.
End session
A Charging Session has ended.
Start transaction
A Charging Transaction has started.
Start system transaction
A new charging transaction has been started by the system because
of an exceptional condition such as Charge Parameter Discovery
without Power Delivery Request while high-level communication.
End transaction
A Charging Transaction has ended.
Power exceeded
The Electric Vehicle has drawn more power than assigned in the
Charging Profile or at the Wallbox.
Renegotiation
A renegotiation has been initiated because the Electric Vehicle has
exceeded the electric current assigned in the Charging Profile.
No ventilation
The Electric Vehicle has requested ventilation, but the Wallbox
doesn't support ventilation.
Meter reading in the transaction history. Might be from different attributes
depending on the type of transaction.
Termination reason at the session history. Might be either “Termination
Reasons Session” or “Termination Reason Transaction” depending on
the type of history entry.
It will be populated with additional information such as "Contract ID" for
the start of a session or the measured current in case of exceeding the
assigned current.