System configuration information
15 / 156
3.2 Software architecture
The KeContact M10 system contains the following main software components.
Load Manager:
The load manager has the following responsibilities:
Controls and coordinates charging sessions for several vehicles on the separate charging stations
(PDCs).
Is offering WEB services for the vehicle manager. These services allow the vehicle manager to initi-
ate, start / stop charging sessions and other activities in response to the according requests of an
electric vehicle using high-level communication.
All necessary activities and events that occur on the different charging stations (sockets) are man-
aged and controlled by the socket manager (PDC manager). This way the socket manager assists
the load manager in managing the separate charging sessions.
The load manager gathers the different information of the separate charging sessions, the used
PDCs and the vehicle information and forwards those data to the charge point manager.
A core component of the load manager is the socket manager:
Represents the network of all connected PDCs and their status.
Forwards requests to the addressed PDCs, handles and reports status changes
Vehicle Manager:
The vehicle manager has the following responsibilities:
Handles communication with vehicles using high-level communication (ISO 15118). Issues requests
to the charge point manager and web service requests to the load manager in order to fulfil loading
requests received by vehicles.
Establishes und closes secure communication sessions with vehicles.
Charge Point Manager:
The charge point manager has the following responsibilities:
Manages the available power and assigns it to the PDCs (for Mode 3 charging) and to electric vehi-
cles (for charging controlled by high-level communication).
Manages the HTML user interface for monitoring (status and current transactions) and entry of con-
figuration data. Access to the monitoring pages of the charge point manager is allowed to anybody
with proper network access.
Pages for configuration and system changes require a login.
User Interface:
The operator of the system connects with a web browser to the KeContact M10.

Table of Contents

Related product manuals