Load management program
65 / 156
6.5.5 Power usage
This screen shows the power usage during a time interval.
Monitoring menu – Power Usage
Please select a day. If the user doesn't enter a day, today will be as-
sumed. For the entry of the day, a date picker widget will be used.
Point in time at which the interval in the power usage table starts for the
selected day.
Number of cars that where plugged in during the time interval.
Number of cars that arrived during the time interval.
Number of cars that left during the time interval.
Maximum number of cars that were plugged in during the time interval.
Overall energy consumed during the time interval (by all vehicles).
Energy consumed will be measured as follows:
For all Wallboxes, the difference between the last meter reading of the
previous period and the last meter reading of the current period will be
calculated. The sum for all Wallboxes will be calculated to get the overall
energy.