Load management program
71 / 156
6.6.1.2 Load Management tab
Charge Point configuration Load Management
Charge Point information
ID:
Unique ID of the Charge Point. In ISO 15118-2, the ID of the Charge
Point is called EVSE-ID. According to ISO 15118-2, it is a globally unique
identifier containing an octet string. In communication with the Electric
Vehicle, the Charge Point ID will be concatenated with the Socket ID to
receive the EVSE-ID.
[default value: Charge Point ID]
Name:
Human-readable name of the Charge Point for presentation purposes.
[default value: Charge Point ID]
Charging strategy parameters
Charging strategy category:
Category of the charging strategy. Characterises the rules that will be
used by the Charging Strategy. Two Charging Strategies with the same
Charging Strategy Category might have different parameters.
Display values:
Fifo for fleets:
Strategy for corporate fleets of EVs based on the “First come, First
serve” principle.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba KeContact Series and is the answer not in the manual?

Keba KeContact Series Specifications

General IconGeneral
Charging powerUp to 22 kW
Protection classIP54
Frequency50/60 Hz
Operating Temperature-25°C to +55°C
Rated current32 A
Connection typeType 2 socket
CommunicationEthernet
Residual current monitoringType A
Output CurrentUp to 32 A