EasyManua.ls Logo

Keba KeContact Series - DIP-Switch Settings

Keba KeContact Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware installation
20 / 156
4.5 DIP-switch settings
Changes in the DIP-switch settings will take effect once the charging station has been restarted!
To do this, press the [Service button] for 1 second or switch the power supply off/on.
DIP-switches
DIP-switches
The DIP-switches are used for the addressing and con-
figuring the charging station and are located under the
connector panel cover.
[DSW1]…configuration (upper DIP-switch)
[DSW2]…addressing (lower DIP-switch)
DIP-switch example
The figure shows for a better explanation, the position
of the DIP-switches for the ON and OFF state.
INPUT/OUTPUT (DSW1) / ONLY FOR STANDARD MODE
Function
DIP-switch
Figure
External enable input [X1]
is used
D1.1
ON=yes
Switch contact output [X2]
is used
D1.2
ON=yes
SmartHome interface via UDP
(details see “UDP Program-
mers Guide”)
D1.3
ON=
enabled

Table of Contents

Related product manuals