First time installation
29 / 156
Selection of the Time zone. Internally, the Load management program
uses UTC. If the user selects a different time zone, conversions happen
at the user interface.
Selection of the user interface language. If there is only one user inter-
face language available, the parameter "Language" is not shown.
Press the [Save] button to save the installation data.
5.2 Making a backup of the Compact Flash card
After finishing the configuration of the system as described in the following chapters, it is recom-
mended to make a backup of the Compact Flash (CF) card, to be able to restore the original sys-
tem parameters.
Turn off the KeContact M10. Navigate through the MMI and select “Shutdown system” (for details
see “KeContact M10 MMI menu”.
Remove the CF card from the KeContact M10 and insert it into a CF card reader.
Use a suitable program to create an ISO image of the CF card. It is not sufficient to copy the files
using the “Copy & Paste” function.